Read the RC design report as the start of an engineer's work

For a generated RC-frame plan, ChatHome.ai can compute a preliminary member design: the slab panels, beams, columns, footings, stairs, lintels and laps of the frame, sized by one stated method. It gives you and your engineer a common starting point: every number on the page is traceable to a stated input, a constant and a clause, and every assumption is printed.

The report is preliminary and gravity-only. It is indicative only, never an engineered design or a safety sign-off, and it is not a bar-bending schedule; an engineer designs and signs every member before construction.

Choose the plan and download

Open a design generated from an RC-frame brief. During a generation conversation, the Design button reads that generated turn and shows the report as a bubble. In Export, find RC design and choose report (.txt, preliminary) for the readable report or (.csv, every member) for one row per member. Both read the stored generated turn, so later hand edits are outside the report, and opening it uses no generation allowance.

A plan that is not an RC-frame plan with frame members answers with the reason instead of a report. The report uses metric units (millimetres, kilonewtons, metres) even when your design is shown in feet.

Choose the regional practice

The site practice setting you use for the bill of quantities applies to the RC design too: it sets the concrete and steel grades the method designs with, and the size of the overhead water tank assumed on the stair core roof. An explicit selection takes priority; otherwise the country named in the brief, then the region on your account, then American. The structure report, the bill of quantities and the RC design read one practice, so the three pages agree.

Read the inputs and their sources first

The report begins with the engineering inputs it designed with: the soil's safe bearing capacity, the concrete and steel grades, the founding depth, the water table and the seismic zone. Each value names its source: from the brief when the brief stated it, the practice's default when it did not, or your own override for that download.

A brief can state these facts in plain words, such as a safe bearing capacity of 150 kN/m², M25 concrete and Fe500 steel, or foundations 1.5 m deep, and the generated plan keeps them. A revision corrects them when you state a new value; a default the brief never stated is never written as if it were the brief's. A per-download override is never saved: the next report reads the stored values again.

The water table and the seismic zone have no default. When the brief does not state them, the report says so and names the code family your country uses for lateral design.

Read the method

The report prints the method it used in full: an IS 456-style limit-state method, with its load values, partial factors, cover, bar sets and the clause each step follows, at the practice's grades. The engineer maps the result to the governing code of your project. Grades below the method's floor are raised to it and the report says so.

The design works gravity only. Lateral loads are not checked: wind, earthquake and lateral earth pressure belong to the engineer, and the report prints that checklist with the seismic code family named.

Read three takedowns and the members

The report prints its own load takedown beside the structure report's and beside the sections the plan was drawn with, and says how far they differ. Then it lists the members: the slab panels with their thickness and bars, the beams with their moments, shears and bars, the columns in at most three section groups with their load, steel, ties and utilization, the footings (pads, combined footings, strips, or a raft when the pads would cover more than half the lowest level), the stairs, the lintels and the lap lengths.

Where the method needs a larger section than the plan drew, the row says so, as a re-size with both sections named. The drawing does not change: the report counts the members it would resize so you and your engineer can see where the drawn frame is light. A section the method cannot size by its own rules is not sized here: the report marks it for the engineer.

Compare it with the structure report

The preliminary structure report checks the drawn members and follows the gravity loads to the ground; the RC design sizes the members a frame would need. Under one practice both assume the same overhead water tank on the stair core and the same bearing value, and both print those assumptions. Read a difference between them as a question for the engineer, not as an error.

Read the designed steel in the bill of quantities

On an RC-frame plan the bill of quantities takes its reinforcement from the RC design where the design sizes a member: the frame columns, beams and plinth beams, the suspended slabs and the lid, and the footings, which become the design's footings in the bill. Everything else stays by a disclosed ratio, and the bill says which is which: designed where the RC design sizes a member, else by a disclosed ratio, never a bar-bending schedule. A revision's quantities change log names the moment the basis changed.

Bring the report into the next conversation

Share the report and the CSV with the matching design, the structure report and the bill of quantities under one practice, and your open questions. Ask the engineer to confirm the inputs on site, choose the governing code, and design and sign every member before construction decisions are made.

Read the preliminary structure report.

Read the bill of quantities.

Explore the structural frame.